Harnessed cables for Siemens | igus® Singapore
readycable® power cable suitable for Siemens 6FX_002-5CK01, base cable PUR 7.5 x d
- Requirements: For extremely heavy duty applications
- Outer jacket: PUR
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- Halogen-free
- Silicone-free
- Flame retardant
- Offshore
- Coolant resistant
- Hydrolysis and microbe-resistant
- Notch-resistant
- Overall shield
- PVC-free
- CFRIP®
- chainflex® class: 6.5.3.1















readycable® signal cable according to Siemens DriveCliq i6FX8002-2DC34-1AD0(3m), extension cable PUR 7.5 x d
- Requirements: For extremely heavy duty applications
- Outer jacket: PUR
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- Halogen-free
- Silicone-free
- Flame retardant
- Offshore
- Coolant resistant
- Hydrolysis and microbe-resistant
- Overall shield
- Notch-resistant
- PVC-free
- CFRIP®
- chainflex® class: 6.5.3.1















readycable® power cable suitable for Siemens 6FX_002-5CK01, base cable TPR 7.5 x d
- Requirements: For extremely heavy duty applications
- Outer jacket: TPE
- Overall shield
- Hydrolysis and microbe-resistant
- Flame retardant
- Silicone-free
- UV resistance: High
- Oil resistance: Oil-resistant according to DIN EN 60811-404, resistant to organic oils according to VDMA 24568 with Plantocut 8 S-MB by DEA
- CFRIP®
- chainflex® class: 6.6.4.1












readycable® signal cable suitable for Siemens 6FX_002-1DC00, base cable PVC 15 x d
- Requirements: For flexing applications
- Outer jacket: PVC
- Oil resistance: No oil resistance
- Silicone-free
- Flame retardant
- Overall shield
- chainflex® class: 3.1.1.1









readycable® signal cable suitable for Siemens 6FX_002-1DC00, base cable iguPUR 15 x d
- Requirements: For flexing applications
- Outer jacket: iguPUR
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- Silicone-free
- Flame retardant
- chainflex® class: 3.1.3.1









readycable® signal cable suitable for Siemens 6FX_002-2AH00, base cable, PVC 15 x d
- Requirements: For flexing applications
- Outer jacket: PVC
- Oil resistance: No oil resistance
- Silicone-free
- Flame retardant
- Overall shield
- chainflex® class: 3.1.1.1









readycable® signal cable suitable for Siemens 6FX_002-2AH00, base cable, iguPUR 15 x d
- Requirements: For flexing applications
- Outer jacket: iguPUR
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- Silicone-free
- Flame retardant
- chainflex® class: 3.1.3.1









readycable® signal cable suitable for Siemens 6FX_002-1DC00, base cable PVC 10 x d
- Requirements: For medium duty applications
- Outer jacket: PVC
- Oil resistance: Oil-resistant according to DIN EN 50363-4-1
- Silicone-free
- Flame retardant
- chainflex® class: 4.2.2.1










readycable® signal cable suitable for Siemens 6FX_002-1DC00, base cable PUR 10 x d
- Requirements: For medium duty applications
- Outer jacket: PUR
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- Halogen-free
- Silicone-free
- Flame retardant
- Offshore
- Coolant resistant
- Hydrolysis and microbe-resistant
- Overall shield
- Notch-resistant
- PVC-free
- chainflex® class: 4.2.3.1














readycable® power cable suitable for Siemens 6FX_002-5CG01, base cable PVC 15 x d
- Requirements: For flexing applications
- Outer jacket: PVC
- Overall shield
- Flame retardant
- Silicone-free
- Oil resistance: No oil resistance
- chainflex® class: 3.1.1.1









readycable® power cable suitable for Siemens 6FX_002-5CG10, base cable, PVC 15 x d
- Requirements: For flexing applications
- Outer jacket: PVC
- Overall shield
- Flame retardant
- Silicone-free
- Oil resistance: No oil resistance
- chainflex® class: 3.1.1.1









readycable® signal cable suitable for Siemens 6FX_002-2AH00, base cable, PVC 10 x d
- Requirements: For medium duty applications
- Outer jacket: PVC
- Oil resistance: Oil-resistant according to DIN EN 50363-4-1
- Silicone-free
- Flame retardant
- chainflex® class: 4.2.2.1










readycable® power cable suitable for Siemens 6FX_002-5CG01, base cable iguPUR 15 x d
- Requirements: For flexing applications
- Outer jacket: iguPUR
- Overall shield
- Flame retardant
- Silicone-free
- UV resistance: Medium
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- chainflex® class: 3.1.3.1










readycable® power cable suitable for Siemens 6FX_002-5CG10, base cable, iguPUR 15 x d
- Requirements: For flexing applications
- Outer jacket: iguPUR
- Overall shield
- Flame retardant
- Silicone-free
- UV resistance: Medium
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- chainflex® class: 3.1.3.1










readycable® signal cable suitable for Siemens 6FX_002-1DC00, base cable PUR 7.5 x d
- Requirements: For extremely heavy duty applications
- Outer jacket: PUR
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- Halogen-free
- Silicone-free
- Flame retardant
- Offshore
- Coolant resistant
- Hydrolysis and microbe-resistant
- Overall shield
- Notch-resistant
- PVC-free
- CFRIP®
- chainflex® class: 6.5.3.1















readycable® power cable suitable for Siemens 6FX_002-5CG11, base cable PVC 15 x d
- Requirements: For flexing applications
- Outer jacket: PVC
- Overall shield
- Flame retardant
- Silicone-free
- Oil resistance: No oil resistance
- chainflex® class: 3.1.1.1









readycable® power cable suitable for Siemens 6FX_002-5CG31, base cable PVC 15 x d
- Requirements: For flexing applications
- Outer jacket: PVC
- Overall shield
- Flame retardant
- Silicone-free
- Oil resistance: No oil resistance
- chainflex® class: 3.1.1.1









readycable® power cable suitable for Siemens 6FX_002-5CG12, base cable, PVC 15 x d
- Requirements: For flexing applications
- Outer jacket: PVC
- Overall shield
- Flame retardant
- Silicone-free
- Oil resistance: No oil resistance
- chainflex® class: 3.1.1.1









readycable® power cable suitable for Siemens 6FX_002-5CG11, base cable iguPUR 15 x d
- Requirements: For flexing applications
- Outer jacket: iguPUR
- Overall shield
- Flame retardant
- Silicone-free
- UV resistance: Medium
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- chainflex® class: 3.1.3.1










readycable® power cable suitable for Siemens 6FX_002-5CG31, base cable iguPUR 15 x d
- Requirements: For flexing applications
- Outer jacket: iguPUR
- Overall shield
- Flame retardant
- Silicone-free
- UV resistance: Medium
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2